Suprema BioStation A2

Observe the following instructions to use the product safely and prevent any risk of injury or property damage.


Warning

Noncompliance of instructions could lead to serious injury or death.


Installation

Do not install the product in a place with direct sunlight, moisture, dust, or soot.

  • A fire or electric shock may occur.

Do not install the product in a place with heat from an electric heater.

  • A fire or electric shock may occur due to overheating.

Install the product in a dry place.

  • Otherwise, a product damage or electric shock may occur due to moisture.

Install the product in a place with no electromagnetic interference.

  • Otherwise, a product damage or electric shock may occur.

The user should not install or repair the product independently.

  • A fire, electric shock, or personal injury may occur.
  • If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be provided.


Operation

Do not allow liquids such as water, beverages, or chemicals get into the product.

  • A fire, electric shock, or product damage may occur.


Caution

Noncompliance of instructions could lead to minor injury or product damage.


Installation

Do not install the power supply cable in a place where people pass by.

  • Product damage or physical injury may occur.

Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker.

  • A product failure may occur.

Use only a power supply adaptor of D.C 12 V and 500 mA or higher.

  • If the proper power is not used, the product may not operate normally.

If installing the product outside where the product is completely exposed, it is recommended to install the product together with the enclosure. Use a separate power supply for Secure I/O 2, electric lock and BioStation A2 respectively.

  • If connecting and using the power supply to these devices together, the devices may malfunction.

Keep the minimum distances between the devices when install multiple devices.

  • Otherwise, RF performance is affect to the other device, the devices may not operate normally.


Operation

Do not drop the product or apply an impact to the product.

  • A product failure may occur.

Manage the password with care not to disclose it to others and change the password periodically.

  • Otherwise, illegal intrusion may occur.

Do not press the buttons on the product forcibly or using a sharp tool.

  • A product failure may occur.

Be careful not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances.

  • Deterioration in fingerprint authentication performance and a product failure may occur.

When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.

  • Otherwise, a product failure may occur.

BioStation A2 uses capacitive buttons. If the environment is moist from wet weather or the product surface is smeared with a lot of water, wipe off the product with a dry towel before using it.


RTC battery
Replacing the battery with an incorrect type of battery may cause explosion.
Discard the battery according to the appropriate regional or international waste regulations.

Suprema BioEntry W2

Observe the following instructions to use the product safely and prevent any risk of injury or property damage.


Warning

Noncompliance of instructions could lead to serious injury or death.

Installation

Do not install the product in a place with direct sunlight, moisture, dust, or soot.

  • A fire or electric shock may occur.

Do not install the product in a place with heat from an electric heater.

  • A fire or electric shock may occur due to overheating.

Install the product in a dry place.

  • Otherwise, a product damage or electric shock may occur due to moisture.

Install the product in a place with no electromagnetic interference.

  • Otherwise, a product damage or electric shock may occur.

The user should not install or repair the product independently.

  • A fire, electric shock, or personal injury may occur.
  • If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be provided.


Operation

Do not allow liquids such as water, beverages, or chemicals get into the product.

  • A fire, electric shock, or product damage may occur.


Caution

Noncompliance of instructions could lead to minor injury or product damage.


Installation

Do not install the power supply cable in a place where people pass by.

  • Product damage or physical injury may occur.

Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker.

  • A product failure may occur.

If installing the product outside where the product is completely exposed, it is recommended to install the product together with the enclosure. Use a separate power supply for Secure I/O 2, electric lock and BioEntry W2 respectively.

  • If connecting and using the power supply to these devices together, the devices may malfunction.

Keep the minimum distances between the devices when install multiple devices.

  • Otherwise, RF performance is affect to the other device, the devices may not operate normally.

 

Operation

Do not drop the product or apply an impact to the product.

  • A product failure may occur.

Be careful not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances.

  • Deterioration in fingerprint authentication performance and a product failure may occur.

When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.

  • Otherwise, a product failure may occur.